Petra Gajski,1 Matej Par,2 Zrinka Tarle,2 and Danijela Marovic2,*

Bongju Kim, Academic Editor

Author information Article notes Copyright and License information PMC Disclaimer

Associated Data

Data Availability Statement

Abstract

This study investigated the effects of different surface treatments and a silane-containing adhesive on the repair bond strength between fresh and aged resin composites. A total of 140 composite specimens were prepared and aged for 24 h or 4 months. Each group was subdivided into seven subgroups (n = 10) depending on the surface treatment (no surface treatment (NT), sandblasting (SAND), or Sof-lex coarse disc (DISC)) in combination with the use of the silane-containing adhesive ScotchBond Universal Plus (SBU) or an adhesive without silane Prime&Bond Universal (P&B). The same composite was used for the repair as for the primary specimen. Specimens were dark stored in distilled water at 37 °C for 28 days. Shear bond strength was tested at a crosshead speed of 0.5 mm/min. The Kruskal–Wallis test with Bonferroni’s post-hoc adjustment (α = 0.05) and the Mann–Whitney U-test were used for the statistical analysis. The results are shown as the median with the interquartile range. The highest bond strength (MPa) was achieved after 24 h in the DISC+P&B (20.39(16.85–28.83)). In the fresh 24 h group, the SAND+P&B (12.25(8.28–15.05)) and DISC+SBU (18.37(15.16–21.29)) were statistically similar. In the 4-month groups, both adhesives and surface treatments performed similarly. The NT, SAND, and DISC groups without adhesives had the lowest bond strength. In the repair of fresh or aged composite, the silane-containing adhesive SBU was not superior to the adhesive without the silane (P&B).

Keywords: shear bond strength, composite repair, aging, silane, adhesives

1. Introduction

With the improvement of bonding, curing, and resin systems, the use of resin-based composite materials in restorative dentistry has become routine for direct restorations [1]. Nevertheless, dentists spend 70% of their chairside time replacing restorations due to secondary caries, fractures, colour changes, inadequate colour matching with the surrounding tooth substrate, insufficient contour, or spacing at the proximal surface. Some errors may occur and can be detected immediately after placement of the filling or later after a short period of time [2]. The treatment choice is either a complete replacement or a repair of the existing restoration. Complete removal of the composite restoration is not desirable, as it is difficult to limit the removal to the composite restoration without damaging the adjacent healthy tooth structure and without creating wider preparations. Once a tooth is restored, a continuous process of replacement of restorations is triggered, eventually leading to tooth loss after several cycles, a phenomenon known as the “restorative cycle” or “death spiral” [3,4,5,6]. For this reason, minimally invasive dentistry favours the repair rather than the replacement of defective restorations [7].

The bond between two composite layers placed immediately one after the other is achieved through an oxygen-inhibited layer of unpolymerised resin [4,5]. However, if the composite has been contaminated, polished, or aged, the bond with the new composite cannot be adequately established due to the lack of an intact oxygen-inhibited layer [8,9]. Several techniques have been proposed, employing macro and micromechanical retention [10]. Macromechanical retention involves creating holes, undercuts, or roughening the surface with a coarse bur. For micromechanical roughening of the surface, acid etching (hydrofluoric or phosphoric acid) or air abrasion have been suggested, followed by silane application in a separate step and the use of adhesive prior to the application of a new composite layer. In addition to sandblasting, surface abrasion with discs is also used to achieve micromechanical retention for better bonding results [11].

Silane is a coupling agent used to create the siloxane bond with the silica-based structures (glass fillers) on one side and the carbon–carbon bond with the methacrylates from the resin matrix on the other [12]. It is not only used for the filler/matrix bond in composites but is also considered an essential bonding agent for the cementation of silica-based materials or silica-coated materials for indirect restorations [13]. For this purpose, commercial products are available in a separate bottle.

With the advent of new silane-containing adhesive formulations, the question arises as to whether the repair procedure could be simplified by using these adhesives without a separate silane application. Currently, there are no official guidelines for the use of silane-containing adhesives in composite repair. A recently published scoping review and other studies investigating this topic [14] brought inconclusive results. Some studies found that there was no difference in the performance of a universal adhesive with or without a silane pretreatment on the surface of the aged composite [15,16,17], while others found a significant difference in favour of additional silane pretreatment [18,19,20].

The repair of aged composites is challenging because the aged composite no longer contains free radicals after the initial polymerisation [21,22]. When composites are exposed to an aqueous environment for a prolonged period of time, such as in the oral cavity, water absorption occurs. Water-saturated composites may pose an additional challenge to repair compared to freshly placed composites, which may still contain some radical species. The aim of this study was, therefore, to investigate the effects of different surface treatments and silane-containing adhesive on the repair bond strength between fresh (24 h) or aged (4 months) resin composites.

The null hypotheses tested in this study assumed no difference in repair bond strength:

  1. Between fresh and aged resin composites;

  2. Among different surface treatments;

  3. Without and with the application of silane-containing adhesives or adhesives without silane.

2. Materials and Methods

In this study, one composite material and two adhesive systems were used (Table 1).

Table 1

Resin-based composite and adhesives used in this study.

MaterialsNameCompositionManufacturerANUFACTURER
CompositeFiltek Supreme Ultra A2B shadeBis-GMA, UDMA, TEGDMA, bis-EMA(6), filler
(78.5 wt%/63.3 vol%)
3M, St. Paul, MN, USA
AdhesivePrime&Bond UniversalBi- and multifunctional acrylate, phosphoric acid modified acrylate resin, initiator, stabilizer, isopropanol, waterDentsply Sirona, Konstanz, Germany
Silane-containing adhesiveScotchBond Universal PlusMDP phosphate monomer, HEMA, 3MTM VitrebondTM Copolymer, filler, Ethanol/water, initiators, silane, dual-cure accelerator, dimethacrylate resins containing BisGMA3M, St. Paul, MN, USA

Open in a separate window

Composite specimens (Filtek Supreme Ultra shade: A2B, 3M) were prepared at room temperature (22 ± 1 °C) in discoid Teflon moulds with a diameter of 5 mm and a height of 2 mm. The moulds were placed on a polyethylene (PET) strip, filled with uncured composite, and covered with another PET strip. The samples were light-cured using a Bluephase Style (Bluephase, Ivoclar Vivadent, Schaan, Liechtenstein; irradiance 1000 mW/cm2) for 20 s on each side. The upper side of the sample in the no-surface treatment group was levelled with the Optrasculpt instrument (Ivoclar Vivadent) and then light-cured in the same way.

The flow chart of the experimental procedure is shown in Figure 1.

Open in a separate window

Figure 1

Flow chart of the study.

A total of 140 composite specimens were prepared and dark stored in distilled water at 37 °C for the following times:

  • (1)

    24 h;

  • (2)

    4 months.

Distilled water was changed every 30 days in the 4-month groups.

Each group was subdivided into seven subgroups (n = 10) depending on surface treatment before performing repair:

  1. No surface treatment (NT);

  2. Al2O3 sandblasting (SAND);

  3. Al2O3 sandblasting + Prime&Bond Universal (SAND+P&B);

  4. Al2O3 sandblasting + Scotchbond Universal Plus (SAND+SBU);

  5. Sof-Lex coarse red disc abrading (DISC);

  6. Sof-Lex coarse red disc abrading + Prime&Bond Universal (DISC+P&B);

  7. Sof-Lex coarse red disc abrading + Scotchbond Universal Plus (DISC+SBU).

In subgroups 2, 3, and 4, sandblasting was performed in a sandblasting unit (Basic classic Fine sandblasting unit, 25–70 µm, 220–240 V, Renfert, Hilzingen, Germany) with 50 μm of Al2O3 sand (Cobra aluoxid 50 µm, Renfert, Germany). In groups 5, 6, and 7, surfaces were abraded with a Soflex red disc (3M™ Sof-Lex™ Finishing and Polishing Discs–Extra Thin/Coarse, 12.7 mm, 8692C, 3M).

After surface treatment, the silane-containing adhesive Scotchbond Universal (3M) or an adhesive without silane Prime&Bond Universal (Dentsply) was applied for 20 s, gently air dried for 5 s, and light-cured using a Bluephase Style (1000 mW/cm2) for 10 s.

The composite used for repair was the same composite used to make the primary specimen, Filtek Supreme Ultra. Repair composite was applied using a cylindrical mould in two layers with a diameter of 3.15 mm and a height of 2 mm. Each layer was light-cured using a Bluephase Style (1000 mW/cm2) for 20 s (Figure 2).

Open in a separate window

Figure 2

Illustration of the specimen.

Specimens were dark stored in distilled water at 37 °C for 28 days. Shear bond strength (SBS) was tested by loading the specimens in a universal testing machine (Inspekt Duo 5 kN; Hegewald & Peschke, Nossen, Germany) at a constant crosshead speed of 0.5 mm/min until fracture.

SBS was calculated according to the following equation:

SBS (MPa) = Fmax(N)/A; (m2)

where Fmax denotes the maximum load, and A denotes the bonded surface area.

The fractured surface of each specimen in both the 24 h and 4-month groups was visually examined to determine whether the fracture traversed the bonded interface (denoted as A for “adhesive fracture”), went through the lower composite specimen (denoted as C for “cohesive fracture”), or the specimen was debonded during the storage in distilled water before testing (denoted as PTF for “pre-test failure”).

Bond strength values were compared using nonparametric statistics to address significant departures from normality due to the pre-test failures, which were attributed to zero values. The comparisons among treatments and adhesives were performed using the independent samples Kruskal–Wallis test with Bonferroni’s post-hoc adjustment. The comparisons between 24 h and 4-month groups were performed using independent samples of the Mann–Whitney U-test. Statistical analysis was performed using SPSS 25.0 (IBM, Armonk, NY, USA). The level of significance for all analyses was 0.05. The results are shown as the median and the interquartile range (IQR).

3. Results

The results of the shear bond strength for the 24 h and 4-month-aged specimens are shown in Figure 3.

Open in a separate window

Figure 3

Shear bond strength for tested groups (n = 10). Data are presented as medians and interquartile ranges. Identical uppercase letters denote statistically similar values within the 24 h group; identical lowercase letters denote statistically similar values within the 4-month group; square brackets denote statistically similar values for comparisons 24 h vs. 4 months.

The treatments without adhesive application, NT, SAND, and DISC, had the lowest values, with no significant differences between them. Only disc-abrasion (DISC) showed slightly, but nonetheless statistically significant, improved SBS for fresh 24 h specimens compared to aged 4-month specimens.

Similarly, for the fresh 24 h specimens, disc-abrasion followed by the application of any of the tested adhesives achieved a higher SBS than sandblasting with adhesives, although not statistically significant. Within the 24 h group, SAND+P&B (12.25(8.28–15.05)) and DISC+SBU (18.37(15.16–21.29)) had statistically similar results. Overall, the highest SBS in the 24 h group was the group with surface treatment DISC+P&B (20.39(16.85–28.83)).

In the 4-month group, there was no statistical difference between sandblasting, disc-abrasion, and any of the tested adhesives. The SBS values of SAND+SBU were statistically similar for comparison between 24 h and 4 months.

The failure mode of each subgroup in the 24 h and 4-month groups is shown in Figure 4. All specimens in the NT, SAND, and DISC groups showed pre-test failure in the 4-month-aged specimens. The treatment without adhesive application and no treatment group showed only adhesive fractures in the 24 h group. The 4-month DISC+P&B group exhibited the highest adhesive failure ratio, and the 4-month SAND+P&B exhibited the highest cohesive failure ratio among all groups. The treatments with sandblasting in the 24 h group showed more adhesive than cohesive fractures, and the treatments with disc showed more cohesive than adhesive fractures.

Open in a separate window

Figure 4

Distribution (percentage) of fracture mode. A: adhesive fracture, C: cohesive fracture, PTF: pre-test failure.

4. Discussion

The composite repair is affected by many factors, including aging of the restoration in a humid and aqueous environment, high water saturation, surface preparation, and others [23]. In this study, different surface treatments and adhesives were evaluated, and SBS was used to measure the repair bond strength of fresh (24 h) and aged specimens (4 months).

In the present study, no significant difference in the repair bond strength values was found when silane-containing adhesive was used. This result is consistent with other studies [24,25]. In 1997, Brosch et al. showed that the application of silane in a separate step and a 120 s penetration prior to adhesive application had a positive effect on the repair bond strength [5]. More recently, in 2019, Flury et al. compared the use of silane in a separate step and subsequent adhesive application with silane-containing adhesive alone and found no statistically significant difference, neither after 24 h nor after 1 year [26]. There are three different mechanisms in the process of composite repair: chemical bond formation to the matrix, chemical bonds to the exposed filler particles, and micromechanical retention achieved through penetration of the monomer components to micro irregularities in the matrix [1]. However, the published literature shows great diversity regarding the effects of silane-containing adhesives. Some studies showed no significant difference in repair bond strength between the silane-containing adhesive and adhesive without silane [24], and one study showed that the adhesives without silane were more efficient than the silane-containing adhesive [25]. In contrast, Chen et al. demonstrated that silane-containing adhesives improve the bond between composites with surface treatment after 24 h in a 37 °C water bath [4].

It is considered that the surface treatment of the old composite is necessary to achieve bonding between old and new composites [5,8,23,27,28,29]. Sandblasting and abrading the surface with discs are surface treatments that roughen the surface to increase the retentive surface available for bonding aged and fresh composites. Both surface treatments cause “micro” retentive features, while diamond stone or green Carborundum stones cause “macro” and “micro” retentive features, respectively; without a bonding system, greater bond strength is expected to be achieved in “macro” retentive features. On the other hand, with a bonding system, a better wetting of the surface occurs as the adhesive resin infiltrates into the composite microscopic surfaces [5,28,29]. The results of the present study are in agreement with the reports about “micro” and “macro” retentive features [5,14,28,29,30]; the lowest bond strength had groups with surface treatments and without the use of adhesives. The combination of surface treatment and use of the adhesive showed better results in both aged and fresh groups.

A restoration that is repaired in the oral cavity has been aging in a humid environment for some time, water saturation of composite resin has been reached and free radical activity has ended [31]. Absorbed water causes the plastification of the matrix, formation of microcracks, degradation of resin, and debonding of the filler–matrix interfaces. The silane coupling layer at the filler–matrix interface can hydrolyse if exposed to water for a prolonged period of time [13]. As the bond deteriorates, the filler particles may detach or separate from the resin matrix, and the surface of the composite may show signs of erosion or wear due to interaction with water, resulting in changes in surface texture and appearance. Therefore, there is no standardized procedure to simulate the aging of composites in oral conditions [1]. In this study, specimens were dark stored in distilled water at 37 °C, first before the repair, either for 24 h or 4 months, and then after the repair for another 28 days. The aged specimens with a disc surface treatment and the use of adhesives showed lower results than the fresh specimens with the same treatment and the same adhesive. This was not the case for the sandblasted specimens with either of the two adhesives used. The possible answer to this question remains to be seen in future studies.

However, the type of composite used could be responsible for the differences in the surface treatments. In this study, we used the same nanocomposite for both the base and the repair. Filtek Supreme is filled with agglomerated and non-agglomerated nanofillers consisting of 4–20 nm of silica and zirconia oxide particles. According to Mitra et al., Filtek Supreme reacts to surface wear by mechanically breaking off the filler particles, which are present in clusters found with round defects on the surface of the specimen after sandblasting with 25 µm of aluminium oxide particles [30,31]. This surface filler loss could have caused a somewhat lower repair bond strength in the present study for both fresh and aged specimens because of the reduced amount of fillers that could react with adhesive/silane-containing adhesive. On the other hand, there are no data in the literature on the surface roughness of composites achieved by using the red Sof-lex disc only, and we can only assume that the use of the disc did not remove many surface filler particles.

Regardless of these differences, all aged specimens were statistically similar in the groups that received a surface treatment (either disc or sandblasting) and one of the tested adhesives. Under the present experimental conditions, this suggests that any micromechanical surface abrasion prior to adhesive application will have a similar effect on composite repair if the repair is not performed immediately after composite application. The silane-containing adhesive was not a decisive factor in improving the bond strength of the repair in the present study. Further studies on repair bond strength with prolonged exposure to water after repair are needed to determine the long-term effects of the silane-containing versus the silane-free adhesive in composite repair.

An important limitation associated with this study is the high variability of the data, which made it difficult to identify statistically significant differences. The bond strength data are generally known for their high heterogeneity, regardless of whether macro [32] or micro-testing [33,34] methods are used, which reduces statistical power and blurs differences between groups. In addition, a high frequency of pre-test failures resulted in skewed distributions that precluded the use of parametric tests, which further reduced the discriminatory power of the statistical analysis.

5. Conclusions

The present study shows that the silane-containing adhesive SBU was not superior to an adhesive without silane (P&B) in the repair of fresh or aged composite. For a successful repair of composite fillings, surface treatment with sandblasting or surface roughening in combination with adhesive is recommended. A purely mechanical pre-treatment without the use of adhesive is not advisable for the repair of composite.

Funding Statement

The research was funded by the University of Zagreb project “Investigation on experimental composites with fluorine and copper modified bioactive glasses”.

Author Contributions

Conceptualization, D.M. and P.G.; methodology, D.M., P.G. and M.P.; software, M.P.; Conceptualization, P.G. and D.M.; Data curation, P.G.; Formal analysis, M.P.; Funding acquisition, Z.T. and D.M.; Investigation, P.G.; Methodology, P.G., M.P. and D.M.; Project administration, D.M.; Resources, Z.T.; Software, M.P.; Supervision, D.M.; Visualization, P.G. and M.P.; Writing—original draft, P.G.; Writing—review & editing, P.G., M.P., Z.T. and D.M. All authors have read and agreed to the published version of the manuscript.

Institutional Review Board Statement

Not applicable.

Informed Consent Statement

Not applicable.

Data Availability Statement

Data supporting the reported results are available on request from the corresponding author.

Conflicts of Interest

The authors declare no conflicts of interest.

Footnotes

Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

References

1. Tezvergil A., Lassila L.V.J., Valittu P.K. Composite–composite repair bond strength: Effect of different adhesion primers. J. Dent. 2003;31:521–525. doi:10.1016/S0300-5712(03)00093-9. [PubMed] [CrossRef] [Google Scholar]

2. Özcan M., Koc-Dundar B. Composite-composite adhesion in dentistry: A systematic review and meta-analysis. J. Adhes. Sci. Technol. 2014;28:2209–2229. doi:10.1080/01694243.2014.954659. [CrossRef] [Google Scholar]

3. Elderton R.J. Clinical studies concerning re-restoration of teeth. Adv. Dent. Res. 1990;4:4–9. doi:10.1177/08959374900040010701. [PubMed] [CrossRef] [Google Scholar]

4. Chen K.K., Chen J.H., Wu J.H., Du J.K. Influence of commercial adhesive with/without silane on the bond strength of resin-based composite repaired within twenty-four hours. J. Dent. Sci. 2021;16:877–884. doi:10.1016/j.jds.2020.12.008. [PMC free article] [PubMed] [CrossRef] [Google Scholar]

5. Brosh T., Pilo R., Bichacho N., Blutstein R. Effect of combinations of surface treatments and bonding agents on the bond strength of repaired composites. J. Prosthet. Dent. 1997;77:122–126. doi:10.1016/S0022-3913(97)70224-5. [PubMed] [CrossRef] [Google Scholar]

6. Hemadri M., Saritha G., Rajasekhar V., Pachlag K.A., Purushotham R., Reddy V.K.K. Shear Bond Strength of Repaired Composites Using Surface Treatments and Repair Materials: An In vitro Study. J. Int. Oral. Health. 2014;6:22–25. [PMC free article] [PubMed] [Google Scholar]

7. Ghavam M., Naeemi M., Hashemikamangar S.S., Ebrahimi H., Kharazifard M.J. Repair bond strength of composite: Effect of surface treatment and type of composite. J. Clin. Exp. Dent. 2018;10:e520–e527. doi:10.4317/jced.54030. [PMC free article] [PubMed] [CrossRef] [Google Scholar]

8. Lucena-Martin C., Gonzales-Lopez S., Navajas-Rodriquez de Mondelo J.M. The effect of various surface treatments and bonding agents on the repaired strength of heat-treated composites. J. Prosthet. Dent. 2001;86:481–488. doi:10.1067/mpr.2001.116775. [PubMed] [CrossRef] [Google Scholar]

9. Turner C.W., Meiers J.C. Repair of an aged, contaminated indirect composite resin with a direct, visible-light-cured composite resin. Oper. Dent. 1993;18:187–194. [PubMed] [Google Scholar]

10. Loomans B.A.C., Ozcan M. Intraoral repair of direct and indirect restorations: Procedures and guidelines. Oper. Dent. 2016;41:S68–S78. doi:10.2341/15-269-LIT. [PubMed] [CrossRef] [Google Scholar]

11. Özcan M., Alander P., Vallittu P.K., Huysmans M.C., Kalk W. Effect of three surface conditioning methods to improve bond strength of particulate filler resin composites. J. Mater. Sci. Mater. Med. 2005;16:21–27. doi:10.1007/s10856-005-6442-4. [PubMed] [CrossRef] [Google Scholar]

12. Konakanchi A., Alla R.K., Guduri V. Silane Coupling Agents-Benevolent Binders in Composites. Trends Biomater. Artif. Organs. 2017;31:108–113. [Google Scholar]

13. Matinlinna J.P., Lung C.Y.K., Tsoi J.K.H. Silane adhesion mechanism in dental applications and surface treatments: A review. Dent. Mater. 2018;34:13–28. doi:10.1016/j.dental.2017.09.002. [PubMed] [CrossRef] [Google Scholar]

14. Neto H.N.M., Leite J.V.C., de Medeiros J.M., e Silva Campos D., de Araújo Ferreira Muniz I., De Andrade A.K.M., Duarte R.M., De Souza G.M., Lima R.B.W. Scoping review: Effect of surface treatments on bond strength of resin composite repair. J. Dent. 2024;140:104737. doi:10.1016/j.jdent.2023.104737. [PubMed] [CrossRef] [Google Scholar]

15. Ugurlu M., Al-Haj Husain N., Özcan M. Immediate and Late Repair of Microhybrid Resin Composites: Effect of Silane Coupling Agent, Universal Adhesives and Photo Polymerization. Eur. J. Prosthodont. Restor. Dent. 2023;31:116–125. [PubMed] [Google Scholar]

16. Fornazari I.A., Wille I., Meda E.M., Brum R.T., Souza E.M. Effect of surface treatment, silane, and universal adhesive on microshear bond strength of nanofilled composite repairs. Oper. Dent. 2017;42:367–374. doi:10.2341/16-259-L. [PubMed] [CrossRef] [Google Scholar]

17. Michelotti G., Niedzwiecki M., Bidjan D., Dieckmann P., Deari S., Attin T., Tauböck T.T. Silane effect of universal adhesive on the composite-composite repair bond strength after different surface pretreatments. Polymers. 2020;12:950. doi:10.3390/polym12040950. [PMC free article] [PubMed] [CrossRef] [Google Scholar]

18. Çakir N., Demirbuga S., Balkaya H., Karadaş M. Bonding performance of universal adhesives on composite repairs, with or without silane application. J. Conserv. Dent. 2018;21:263–268. doi:10.4103/JCD.JCD_11_18. [PMC free article] [PubMed] [CrossRef] [Google Scholar]

19. Hoseinifar R., Shadman N., Mirrashidi F., Gholami S. The effect of silane-containing universal adhesives on the immediate and delayed bond strength of repaired composite restorations. Dent. Res. J. 2021;18:87. doi:10.4103/1735-3327.328755. [PMC free article] [PubMed] [CrossRef] [Google Scholar]

20. da Silva C.L., Scherer M.M., Mendes L.T., Casagrande L., Leitune V.C.B., Lenzi T.L. Does use of silane-containing universal adhesive eliminate the need for silane application in direct composite repair? Braz. Oral. Res. 2020;34:4037. doi:10.1590/1807-3107bor-2020.vol34.0045. [PubMed] [CrossRef] [Google Scholar]

21. Boyer D.B., Chan K.C., Reinhardt J.W. Build-up and Repair of Light-cured Composites: Bond Strength. J. Dent. Res. 1984;63:1241–1244. doi:10.1177/00220345840630101501. [PubMed] [CrossRef] [Google Scholar]

22. Swift E.J., LeValley B.D., Boyer D.B. Evaluation of new methods for composite repair. Dent. Mater. 1992;8:362–365. doi:10.1016/0109-5641(92)90020-D. [PubMed] [CrossRef] [Google Scholar]

23. Shahdad S.A., Kennedy J.G. Bond strength of repaired anterior composite resins: An in vitro study. J. Dent. 1998;26:685–694. doi:10.1016/S0300-5712(97)00044-4. [PubMed] [CrossRef] [Google Scholar]

24. Soderholm K.J., Roberts M.J. Variables influencing the repair strength of dental composites. Scand. J. Dent. Res. 1991;99:173–180. doi:10.1111/j.1600-0722.1991.tb01881.x. [PubMed] [CrossRef] [Google Scholar]

25. Saunders W.P. Effect of fatigue upon the interfacial bond strength of repaired composite resins. J. Dent. 1990;18:158–162. doi:10.1016/0300-5712(90)90059-N. [PubMed] [CrossRef] [Google Scholar]

26. Flury S., Dulla F.A., Peutzfeldt A. Repair bond strength of resin composite to restorative materials after short- and long-term storage. Dent. Mater. 2019;35:1205–1213. doi:10.1016/j.dental.2019.05.008. [PubMed] [CrossRef] [Google Scholar]

27. Bonstein T., Garlapo D., Jone D., Jr., Bush P.J. Evaluation of varied repair protocols applied to aged composite resin. J. Adhes. Dent. 2005;7:41–49. [PubMed] [Google Scholar]

28. Cavalcanti Nóbrega A., Fonseca De Lima A., Rezende Peris A., Hiroyuki Ogata Mitsui F., Marchi G.M. Effect of surface treatments and bonding agents on the bond strength of repaired composites. J. Esthet. Restor. Dent. 2007;19:90–99. doi:10.1111/j.1708-8240.2007.00073.x. [PubMed] [CrossRef] [Google Scholar]

29. AlOtaibi A.F.A., Taher N.M. Effect of surface treatment on the repair bond strength of OMNICHROMA and Charisma Diamond ONE resin composites bonded to variable substrates. Heliyon. 2023;9:e17786. doi:10.1016/j.heliyon.2023.e17786. [PMC free article] [PubMed] [CrossRef] [Google Scholar]

30. Junior S.A.R., Ferracane J.L., Della Bona Á. Influence of surface treatments on the bond strength of repaired resin composite restorative materials. Dent. Mater. 2009;25:442–451. doi:10.1016/j.dental.2008.09.009. [PubMed] [CrossRef] [Google Scholar]

31. Mitra S.B., Wu D., Holmes B.N. An application of nanotechnology in advanced dental materials. J. Am. Dent. Assoc. 2003;134:1382–1390. doi:10.14219/jada.archive.2003.0054. [PubMed] [CrossRef] [Google Scholar]

32. Par M., Tarle Z., Hickel R., Ilie N. Dentin Bond Strength of Experimental Composites Containing Bioactive Glass: Changes During Aging for up to 1 Year. J. Adhes. Dent. 2018;20:325–334. [PubMed] [Google Scholar]

33. Par M., Steffen T., Dogan S., Walser N., Tauböck T.T. Effect of sodium hypochlorite, ethylenediaminetetraacetic acid, and dual-rinse irrigation on dentin adhesion using an etch-and-rinse or self-etch approach. Sci. Rep. 2024;14:6315. doi:10.1038/s41598-024-57009-x. [PMC free article] [PubMed] [CrossRef] [Google Scholar]

34. Oltramare R., Par M., Mohn D., Wiedemeier D.B., Attin T., Tauböck T.T. Short-and long-term dentin bond strength of bioactive glass-modified dental adhesives. Nanomaterials. 2021;11:1894. doi:10.3390/nano11081894. [PMC free article] [PubMed] [CrossRef] [Google Scholar]

Articles from Materials are provided here courtesy of Multidisciplinary Digital Publishing Institute (MDPI)

Effect of Silane-Containing Adhesives on Repair Bond Strength between Fresh and Aged Composite Materials—A Pilot Study (2024)
Top Articles
Latest Posts
Recommended Articles
Article information

Author: Duane Harber

Last Updated:

Views: 6537

Rating: 4 / 5 (71 voted)

Reviews: 94% of readers found this page helpful

Author information

Name: Duane Harber

Birthday: 1999-10-17

Address: Apt. 404 9899 Magnolia Roads, Port Royceville, ID 78186

Phone: +186911129794335

Job: Human Hospitality Planner

Hobby: Listening to music, Orienteering, Knapping, Dance, Mountain biking, Fishing, Pottery

Introduction: My name is Duane Harber, I am a modern, clever, handsome, fair, agreeable, inexpensive, beautiful person who loves writing and wants to share my knowledge and understanding with you.